Chemical Attack- If your fabric filter bags have deteriorated down the entire length of the bag, then the failure is likely due to an exposure of acid or alkaline outside of what your filter media can withstand. Your gas/ dust pH is among the variables considered to determine the best filter media and fabric construction for your application. There may be blotches, water stains, and discoloration visible on the failed bag.
Read more below.